Copeland compressor nomenclature pdf free. Copeland Discus With CoreSense Protection vs.

Copeland compressor nomenclature pdf free The Coresense Protection module for Discus compressors combines oil and motor protection into . 801 = std. Filename/Presenter-Topic: 1/9/2012 . Key features include: Product 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. Whether used in stand-alone, tandem or trio configurations, the broad ZP Copeland scroll line-up meets today’s market requirements Is this PDF compressor free to use? Yes! Like our other tools, our online PDF compressor tool is free to use for reducing file sizes. The scroll set is mounted at the upper end of the rotor shaft of the motor. 6 Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 * Units with a compressor RLA under 6A do not require pressure controls for UL listing. To ensure safe operation, a high pressure control must be used in all applications. Copeland ZPK6 Scroll Compressor Best in class compressor for 2015 residential minimum standards • Complete line of 1-5 ton compressors for residential and commercial applications • 2-5% effi ciency improvement • Preferred compressor for 2015 minimum energy effi ciency standard • Better sound quality • Introduces our smallest 1 ton Copeland Scroll Digital compressor can be used in a variety of applications. Note that Stream 4M* and 6M* compressors are covered in a different manual see – AGL_Stream_ST_A2L_A1_4M_6M_EN "Copeland™ Stream Semi-Hermetic Compressors". technical data Emerson offers two types of AC drives to be paired with Copeland variable speed 2-15 ton scroll compressors. of compressors in parallel 2 / 3 / 4 Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. It lists Copeland compressor models and their equivalents in various tonnages from 1. The compressor superheat at suction should be controlled such that it is always above 36°F (2. percent of load is shown in Figure 3 for a 3D Discus digital compressor. Copeland compressors undergo numerous improvements every year. pdf), Text File (. Contact Now. The ZR*KC and ZP*KC scrolls outlined in this bulletin range in size from 84,000 to 190,000 Btu/hr (24. Refer specification for 60 Hz model selection. NOMENCLATURE • CR7, CR6, CRKF MODELS - X X X - X X X Product Variations Numbers will be assigned as follows: 1. 5x 22. Protection. Temp. Also for: Copeland k series, Copeland l series, Copeland s series, Copeland 2d series, Copeland 3d series, Copeland 8d series, Copeland 6t series, compressor will restart once the resistance drops below There are a select few 2D/3D Discus compressors that also use PTC Sensors. S. R22 Power Current Evap. Model Variation A number or a letter, assigned to indicate different model types within any one family series. Remove refrigerant from both the high and low side of the compressor. Particular emphasis has been placed on the user's safety. Bristol Compressors International, Inc. 5x 7. Stream compressors equipped with Next Gen CoreSense are fully interchangeable. It is the most efficient and durable compressor Emerson has ever developed for air conditioning, refrigeration and heating applications. ZPD Digital Scroll Compressor Line-up R410A ZRD Digital Scroll Compressor Line-up R407C ZRD*KRE Digital Scroll Compressor Line-up R513A kW Cooling 5 10 35 ZPD (3Ph) 40 45 50 60 80 Nomenclature 06 Sanitary heating 07 Residential heating 37 District heating 45 Industrial heating 50 Variable speed series 57 Contact lists 60. 5 - 17 Offset Mounting Rail Horizontal/Vertical Mount Copeland semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, condensing units or as multi-compressor equipment. An example would be the ZP90KCE-TFD, which has 90,500 But/hr (26. We Also Have Other Nominal Voltage Options Available For Overseas Market. 2 About this guideline This guideline is intended to enable users to ensure the safe installation, starting, operation and maintenance of Copeland Scroll™ compressors. Keep all non-essential personnel away from the compressor during service. The maximum cut out setting is 650 psig (45 bar). com/OPI to determine its compressor model. Airor water-cooled When Copeland first pioneered the use of scroll technology in compressors, it changed the industry forever. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit • Asbestos-free gaskets To attain the Copeland certified compressor status, over 500 parts are either replaced or recalibrated to Emerson’s latest engineering standards. a subsidàryoflngersoll Rand or Copeland Scroll, a division of Emerson Climate Technobgies Inc. 20/0511-1111/E 3 2. replacement compressor and The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 Observe all applicable standards and codes for installing, servicing, and maintaining electrical and refrigeration equipment. The Condensing unit voltage range is For additional information, please refer to Copeland Mobile. a external inherent protection. 276. Particular emphasis has been placed on the user’s safety. 5 4 4. Code 208/230-3 200-3 C 460-3 380/420-3 D 575-3 - E 265-1 220/240-1 J 265-1 - Q NOMENCLATURE • COPELAND SCREW COMPRESSOR Body Type Code C H D Description Lubricant O = R22 E = HFC Compact Semi-hermetic Open Drive S C H 2 - 9 0 0 0 Copeland Screw Compressor Comp. It is the most efficient and durable compressor Emerson has ever developed for air-conditioning and refrigeration. Use a recovery machine and cylinder designed copeland-cf-and-cs-compressor-catalogue. These application guidelines deal with all vertical single Copeland Scroll compressors for CopelandTM Reciprocating Compressors Partner For All Your Cooling Needs With Energy Efficient And Rugged Designs 2 KCE to HP R22, R134a 1/6 1/2 KCJ 1 to 1 ¼ HP R22, CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A You deserve to be as informed as possible about the products you purchase. Securely fasten the protective terminal cover or molded plug to the compressor, and 2. The HFC Solution operation of the air conditioner compressor. By leveraging the power of variable speed technology, Copeland compressors Nomenclature Z P V 030 H E - 3 X 9 - X X X Family Series Z Scroll A1 Y Scroll A2L/A3 Modulation V Variable Speed W Variable Speed EVI Optional 2nd Position VT Copeland™ CF Compressor for Low Temperature Refrigeration Click to view our Accessibility Policy and contact us with accessibility-related issues Skip to Navigation Copeland Scroll Compressor for CO2 Subcritical Refrigeration (R-744) BULLETIN NO: AE4-1372 R7 Safety Important Safety Information 2 Nomenclature ZO D 34 K 3 E - TFD – 269 Z = Compressor family: Scroll O = Refrigerant: R744, subcritical operation D = Digital Model; Blank= Standard Model Copeland Scroll compressor are described in Figure 1 of this bulletin. An example would be the ZP31K7E-PFV, which has 31,500 Btu/hr (9. Compressor Data Compressor mechanical, electrical, and performance data are available online at Copeland Mobile. View online or download Emerson Copeland Discus Series Application Manuallines We have 1 Emerson Copeland Discus Series manual available for free PDF download: Common Information about Copeland™ Semi-Hermetic Compressors. 1 2. • Keep all non-essential personnel away from the compressor during service. 5 = 7. Therefore, the information in this manual relates to Copeland Stream semi-hermetic compressors with standard equipment and COPELAND 3DSDR17ME-TFD air compressor pdf manual download. The semi-hermetic reciprocating compressor family consists of different ranges: The K-Series and L-Series from 0. The range is available from 50-200HP with a combination of 2, 3 or 4 compressors in a rack. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD • Allow time for the compressor to cool before servicing. txt) or read online for free. 44r3) represents the compressor family series and indicates tandem compressor digit 3 displacement and valve plate a letter only, arbitrarily assigned for each 2. 2kW) cooling compressor range (ZR90K* to ZR19M*, ZP180K*) with the new A/C SUMMIT compressor range (ZR94K* to ZR190K* and ZP90K* to ZP182K*, from 7. 2002ECT-165 R9. Icon explanation. Copeland Discus Series air compressor pdf manual download. Copeland Scroll ZR KC Series air compressor pdf manual download. 23 AE4-1414 May 2017 ZPV066 & ZPV096 Copeland Scroll™ Variable Speed Compressors %PDF-1. United States English Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. Upon claim to Copeland, this warranty applies when such defect Copeland Compressor - OEM BOM Copeland Compressor - service Yes Copeland Compressor - service BOM Copeland Compressor - service Yes Nomenclature 7 Application Considerations Operating Envelopes 7 High Pressure Control 7 Assembly Line Procedures Low Pressure Control 7 The 6-to-15-ton Copeland Scroll compressors do not have internal pressure relief valves. The BOM (Bill of Material) indication is part of the nomenclature. The latest in technology and value Drive components Single-phase drive assembly Filter board Toll Free: 800 844 3426 Tel: +966 3 8147560 Fax: +966 View and Download Emerson Copeland Discus Series application manuallines online. Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. However, the procedures can be 2. 0 ZPV 021 028 034 038 041 ZHV 021 034 ZHV models for hot water heating applications. 1°C),. • Smooth operations are made possible by the continuous compression process. These models of Copeland Scroll compressors do not have internal pressure relief valves. 5 HP (all BOM) and 10–15 HP (BOM 567) compressors are supplied with internal thermal protectors that prevent • The Copeland Scroll compressor Copeland Cross Reference - Free download as PDF File (. For additional bulletins and compressor information, please refer to Copeland Reciprocating Compressors Partner For All Your Cooling Needs With Energy Efficient And Rugged Designs FHP Applications KCJ ¼ to 1HP R22, R134a, R404A * Used for nomenclature purpose only. Nomenclature 33-100% range. Copeland Scroll two-stage compressors lead the industry with a greater level of comfort and energy effi ciency, saving up to 25 Copeland Scroll two-stage compressor nomenclature ZP S30K 5 E– P F V –130 Z Scroll Family Series AC, R-410A/B Two-stage Nominal Capacity at Rating Condition Nomenclature 06 Bill of Material 06 Operating Envelopes 07 Product Line-up 07 • Engineered for optimum performance with today’s chlorine-free refrigerants. 5kW) cooling capacity at the AHRI high temperature air conditioning rating point when operated at 60 Hz. CoreSense Protection is noted by a ' C ' in the build of materials, e. Nomenclature Emerson Multi-Compressor Pack E M P - 4 4 M 0 8 0 L K - X X X Compressor family 4M/6M Stream (4/6 - cylinder) No. 5 hp to 4 hp are available as air-cooled or water-cooled versions 2. Also for: Copeland scroll zp10-31k6, Copeland scroll zp34-54k6. Likewise, to eliminate the reverse rotation sound at shut down the compressor is unloaded 0. There are a few important differences outlined below that must be observed when designing a system with the Copeland Scroll UltraTech two step compressor. Number –230 indicates a standard compressor B/M and model The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. 3 3. 3PA3R85KL- TFD-C. 3 2. 00. xx8 will identify units under 6A that are listed, but do not have pressure controls. DWM Copeland Designation (Old Models) 10. ' Product Description The ZPV063 variable speed compressor has a speed range of 1000 (refer to operating envelope for low select an appropriate drive for the compressor application. 23 Speed Adjustment Requirements . As envi-ronmental regulations move our world toward a cleaner, safer tomorrow, Copeland continues to lead the way in rec-iprocating technology with the introduction of the new CF and CS compressors, designed specifically for chlorine-free refrigeration applications. Most Common Regions. Check that the compressor is properly grounded per the applicable system and compressor requirements. The Copeland Scroll variable speed compressor will be referred to throughout this bulletin as the 'variable speed scroll' or the 'compressor. 5 seconds before shut down. Motor Protection. • For A3 refrigerants (R290) remove refrigerant from both the high and low sides of the compressor. This bulletin describes the operating characteristics, design Our compressors are available to support worldwide equipment needs, with many choices of refrigerants and electrical variations, and every compressor is backed by Copeland’s international reputation for quality and reliability. During the time the members are Nomenclature The Copeland Scroll Digital compressor model numbers are designated by a Compressor_catalog_copeland - Free ebook download as PDF File (. Whether it’s a single-circuit packaged system or a multi-circuit rooftop system, the Copeland Scroll Digital compressor offers a reliable and affordable solution for the toughest application Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z Compressor Motor Specifications . & Diagnostics . Signal Word Definitions The signal word explained below are used throughout the document to indicate safety messages. Since then, Copeland scroll compressors have been installed over 170 million times and the technology remains at the compressors, condensing units or as multi-compressor equipment. 5 21. Nameplate Information. Copeland Scroll™ variable speed compressor in a safe and reliable manner. Both these drives have integrated compressor electronics* technology and RS485 Modbus® communication as a standard. 200 = std. For compressor accessories and service parts, please refer to Emerson Online Product Information (OPI). The guide includes model numbers, View and Download Emerson Copeland Scroll ZPS KC Series bulletin online. 2. Set your Compressor and Condensing Unit detailed product information result view: Default (All Collapse) Or select from the list of sections below: Default (none) Summary Performance Components Service Parts Features Accessories Electrical Components Drawings Nomenclature Miscellaneous Bill of Materials Compress PDF file size while preserving quality. For additional bulletins and compressor information, please refer to compressor, the Copeland™ Digital Compressor Controller (see AE8-1328) delays loading the compressor for . 22 Compressor Refrigerant Charge Limits Table . About this guideline. Advanced Scroll Temperature Protection (ASTP) A Therm-O-Disc™ temperature-sensitive snap disc provides compressor protection from discharge gas overheating. ZPD83KC, ZPD91KC, ZPD104KCE, ZPD122KCE, and . Copeland Scroll Compressors Bom Copeland Discus compressors. PDF: 182 kB: Download: Copeland Scroll™ Compressor Eliminates Issues at Meat Processing Facility: English, Français: PDF: 574 kB: Download: Supermarket Becomes More Eco-Friendly Using Copeland Scroll™ Compressors: English, Français: PDF: 177 kB: Download: Case Study - Unique Refrigeration System Leverages Copeland Digital Scroll Compressor cycling problem solved with Copeland Discus Digital™ compressors: English: PDF: 471 kB: Download: Hypermarket Achieves Efficiency Goals with Digital Modulation: English: PDF: 582 kB: Download: Name Languages Type Copeland™ Discus™ Compressor Replacement Guide: English, Français: PDF: 728 kB: Download: Where to Buy. Copland, with our partners, will provide global solutions to improve human The ZP*KZ scroll compressors are qualified for use with the R410A refrigerant. The document provides details on compressor nomenclature and specifications. / Cond. 6 to 10 Ton Two-Stage Compressors. 50 Hz. 1 Common information about Copeland™ semi-hermetic compressors This manual covers all Copeland semi-hermetic compressors. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard D7. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z P V 038 Nomenclature 7 Application Considerations 7 Internal Pressure Relief (IPR) Valve 7 Discharge Temperature Protection 7 The model numbers of the Copeland scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Other available information includes: AC Compressor Product Guide (2008ECT-113) Copeland Scroll ZRK5 Cross Reference Guide (2009ECT-94) copeland-scroll-compressors-bom-overview-technical-information-en-gb-4848778 - Free download as PDF File (. Copeland Discus With CoreSense Protection vs. 21. 4121, or contact your local Bristol Compressors Distributor 3 FROM: CopelandTM Marketing – Air Conditioning SUBJECT: Introducing a new generation of 6-40T Commercial Copeland ScrollTM Compressors optimized for R410A, R32 and R454B Introduction Emerson is pleased to introduce a new generation of 6-40T Commercial scroll compressors, with the first models launching in February 2020. This allows the compressor to start unloaded, resulting in low inrush CopelandTM Reciprocating Compressors Partner For All Your Cooling Needs With Energy Efficient And Rugged Designs 2 KCE to HP R22, R134a 1 /6 1 2 KCJ 1 to 1 ¼ HP R22, CR Series Compressor Nomenclature C R 62 K Q M T F D XXX XX C Series Compressor Compressor Family Series Refrigerant Identifies Code R P Refrigerant R22/R407C/R404A 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. 5 to 5 tons. copeland comp Listed here is some of the information that might be obtained from the nomenclature of a compressor’s model number: The physical characteristics of the compressor series, such as its footprint, body dimensions, and layout of discus copelametic® compressor model number nomenclature compressor cooling code description a air cooled d discus r refrigerant cooled t std. Modular design for ease of fit (separate fi lter and choke) • For use with 2-5 ton variable speed compressors 17-1234 Low Ambient Compressor Operation 17-1260 Compressor Overheating 17-1268 Compression Ratio as it Affects Compressor Reliability 22-1182 Liquid Refrigerant Control in Refrigeration and Air Conditioning Systems For more information, visit EmersonClimate. 1 Common information about DWM Copeland™ semi-hermetic compressors This manual covers all DWM Copeland™ semi-hermetic compressors. It is the most efficient and durable compressor Emerson Climate Technologies has ever developed for air-conditioning and refrigeration. So only Copeland certified compressors can deliver the most energy-efficient, reliable operation, every time. 1 to 5 Ton ZP*K6 R-410A Copeland Scroll but Emerson’s The orientation of the electrical connections on the grommet design and durometer recommendation WWW. Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. com and login to the Customer Portal to view Online Product Information COPELAND - Free download as PDF File (. 5 - 10. Other performance data available to the system scroll compressors outlined in this bulletin range in size from 14,650 Btu/hr to 82,000 Btu/hr (4. These application guidelines deal with all vertical single Copeland Scroll compressors for Compressor mechanical, electrical, and performance data are available online at Copeland Mobile. DLT Protection Motor Protection Oil . For compressor accessories and service parts, please refer to Copeland Online Product Information (OPI). pdf - Free download as PDF File (. No software to install, secure & free. Nomenclature The Copeland Scroll compressor model numbers is designed with the proven Copeland Stream semi-hermetic compressors. It explains that compressor names use letters and numbers to indicate family, series, capacity, variations and electrical codes. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. 5T various Discus nomenclature specifications. two stage w water cooled primary application range r = ari high temp, rated @ 45/130 s = ari med temp, rated @ 20/120 f = ari low temp, rated @ -25/105 compressors, Copeland takes pride in continuously innovating its products. 3 - 24. We have 1 Emerson Copeland D6D Series Compressor manual available for free PDF download: Application Manuallines Nomenclature. This new range of compressors features a significant size, weight, and sound reduction in all models. Copeland™ Digital Compressor AE8-1328 Controller CoreSense™ Diagnostics v2. 44 x 9. Copeland ScrollTM Product Range March 16, 2012 This Guide For India Market Covers Single Phase 220-240V And Three Phase 380-420V Models. 4 Copeland™ Scroll ZW for heat pump Copeland ZW heat pump compressors employ EVI technology to create a strong “core” for any heating system. compressor model nomenclature ae 4 440 y aa 1a aea 4 440 y xa compressor family (first two digits) application first digit is the number of digits in btu/h capacity refrigerant voltage release variant release variant (the third digit) last two digits are the first two digits in rated btu/h capacity ae ag ah aj ak an av aw az rg rk sa sf ta tc Copeland Scroll™ compressors for high, medium, and vibration free operation by axially unloading the compliant scrolls. digit 2 compressor type a = standard air cooled d = discus refrigerant cooled r = standard refrigerant cooled t = two stage w = standard water cooled a digit in this position (e. The matched pairs have been designed for maximum efficiency and reliability. For additional bulletins and compressor information, please refer to Copeland Online Product Information (OPI). Copeland_discus_model_chart. 0 8. Suction Gas-Cooled Compressors. 1 1. Theory of Operation Digital capacity control is achieved by axially separating the scroll members. comp. 10. CoreSense Diagnostics Feature Comparison . Operating principles of the Copeland Scroll compressor are described in Figure 7. COMCall us at 1. . 5 3 3. 2kW) cooling All 2D, 3D, 4D & 6D Copeland Discus Compressors Have CoreSense Technology On Board . Other Than R22, Options Of R134a / R407C / R410A Are Also Available. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. 5 hp to 4 hp are available as air-cooled or water-cooled versions and use reed valve technology. - Ensure that materials and wiring do not touch high temperature areas of the compressor. 3 BOM Variation industry in compressor efficiency and reliability. Modular design for ease of fit (separate fi lter and choke) • For use with 2-5 ton variable speed compressors Emerson offers two types of AC drives to be paired with Copeland variable speed 2-15 ton scroll compressors. Capacities are at 50/115 operating conditions. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Copeland scroll compressors are manufactured according to the latest relevant European safety standards. We enjoyed a strong reputation for quality products a n d e f f i c i e n t s e r v i c e i n D u b a i . 8. 7 %âãÏÓ 8114 0 obj >stream hÞ´›Û®d¹qm eÿA%ɸ €!@ð çÀ°p à‡B?”[u¤†»«„r °ÿÞäÊ +¹ ßü qt /¹¸f ¹'ƒ]Þ o]ßz ëöÖô±È«½ Ç[}Ìÿ, òV×ç­ÌÿUÕ·&mþOúü'y¼y³úV|¶*ÅÄßj5{+bÖÞê¨óÓÞ‡Ìú>ÿ»ªù[ uÖÒÚê›\ߪÕ"ob}Ì ½è›ÎÊo­y­oª¶¾TQy3 êü®ÖÛlPÕë }}ªÝíÍm6 + Nomenclature/Bills of Material 13 Focused Parts 16 be free from defect in material and workmanship. 2011DS-4 F-Line R1 (11/15)4 Emerson Climate Technologies R-404A Medium/High Temp Copeland Scroll air-cooled condensing units Model Compressor 0 5 10 15 20 25 30 35 40 45 90° Ambient View and Download Emerson Copeland Scroll ZR KC Series bulletin online. Nomenclature • M-Line Units Condensing Unit Family Series Hermetic M Temperature Application Code High Temperature Medium Temperature Low Temperature Extended Medium Temp Copeland™ CF Compressor for Low Temperature Refrigeration Click to view our Accessibility Policy and contact us with accessibility-related issues Skip to Navigation Copeland Scroll compressors brochures or Copeland™ Products Selection Software. 2 Nomenclature The model designation contains the following technical information about the compressors: 4 AGL_AC_ST_ZRKRE_E_Rev02 2. 2 °C) to avoid oil dilution in the compressor but low return gas temperature enough to keep the compressor discharge temperature below 250°F (121. 5 6. Other drawing formats (IGES, DXF, and STP) can be obtained by contacting your Application Engineer. 2 Nomenclature The model designation contains the following technical information about the The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. 5x 9. Air- or Water-Cooled Compressors. indd 2 12/6/2013 10:05:25 AM. and component parts 201 = 201 and larger will be assigned for all other variations. units. The following Application Engineering bulletins should be consulted for non-modulating scroll ZPD104KCE, ZPD122KCE AE4-1303 ZPD103KC, ZPD120KC, ZPD137-182KC, ZRD94-125KC AE4-1312 ZRD36-81KC. Tables then list mechanical dimensions and specifications for various 2. 0 115 1 60 230 1 60 208-230 1 60 9. 4DH3R22ML-TSK-C00. 3-4. 120 volt control. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. The semi-hermetic reciprocating compressor family consists of different ranges: The K- and L- series from 0. 3. 1 Nomenclature; Download this manual; AE4-1400 R2. Cross Reference: Trane-SF-Danfoss-Copeland *SF Compressors available April 2016. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. United States English The ZP*KZ scroll compressors are qualified for use with the R410A refrigerant. replacement compressor and component. Electrical Codes 60 Hz. g. The rotor shaft axis is in the vertical plane. Copeland Scroll AC Compressor Supplier in China, We Can Supply You with Copeland Scroll Heat Pump Compressor, Refrigeration Compressor, Freezer Compressor, etc. ABOUT US Copeland Compressors Suppliers in Dubai We are the main distributor and supplier for HVAC related products and spare parts for numerous esteemed companies worldwide. The high-pressure control Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. The previous generation will be phased out by the end of 2010. 70 frame family (7" diameter shell) and include a number of features outlined in the matrix below. These application guidelines Air Compressor; Copeland 3D Series; We have 2 Emerson Copeland 3D Series manuals available for free PDF download: Application Manuallines Nomenclature. 5 1 1. These models will have motor protection through CoreSense technology as well. used in copeland cond. Oil . 11 for AE8-1368 compressors, and bulletins AE4-1331 and AE4-1365 for ZPS*K4 compressors. They Copeland Scroll Digital compressors have one Scroll compression set driven by a single- or three-phase induction motor. txt) or view presentation slides online. and European Safety Standards. Copeland™ Single Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. 61 MOTORS 621–659 HONEYWELL 537–583 JOHNSON/RANCO 479–535 ACCUMULATORS/ RECEIVERS 260–279 SPORLAN 169–248 OIL/RECOVERY/ FITTINGS 123–159 Dwm Copeland Manual - Free download as PDF File (. Also for: Copeland 4dadf47ke-tsk, Copeland 4djxr28me-tsk, Copeland 6djxr40me-tse. ZP Copeland scroll compressors are perfectly suitable for air-cooled chiller systems up to 900kW (1100 kW if water-cooled) featuring high comfort and superior seasonal efficiency (SEER / SEPR / SCOP). An example would be the YA31K1E-PFV, which has 31,000 Btu/hr (9. Use a recovery 2. Modulation is achieved by venting a portion of the gas in the first suction pocket back to the low side of the compressor ordering compressor with water coil. EVI technology effectively expands the operating respect to the equivalent fixed capacity Copeland Scroll compressors. one protector, (line break). 7 to 15 TonCompressors. From this site, compressor drawings (PDF format) can be downloaded. Safety instructions. You can always rely on the availability of Copeland hermetic compressors, regardless of quantity or time SERVICING COPELAND® BRAND COMPRESSORS free performance. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson Climate Technologies since 1979. 240 volt control. About These Guidelines. Other content in this Stream Copeland Scroll ZRK5 compressors are offered in an -800 bill-of-material option, such as ZR25K5E-PFV-800, that includes the compressor with molded plug wiring harness, mounting parts and installation instructions. Comm. use Digital scroll compressors are the preferred choice for process cooling, refrigeration racks, refrigeration units, VRF, rooftop and air handling unit systems. An example would be • All Copeland Scroll compressors are designed with a discharge check valve that isolates the high pressure discharge gas. Copeland 2-ton scroll air conditioner compressor is suitable for R22 and R410 refrigerants. Scribd is the world's largest social reading and publishing site. The drive will power the compressor, control the compressor running speed and communicate with the master controller Oil-Free Centrifugal Compressor Variable Frequency Drives Toggle submenu for: Topic Connectivity, IoT, and Insights Contractor Training, Tips & Safety Download PDF Expand Fullscreen Copeland compressor Parts and accessories Explore a cumulative list of parts and accessories for the Copeland™ compressor. This allows the compressor to start unloaded, resulting in low inrush currents. 5T CR14K6-PFV CR14K7-PFV These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). This generates less vibration than reciprocating technology. 1 seconds at start up. Nomenclature Q F 1 8 5 L E-T W D-2 0 2 Family Q – Copeland Scroll™ Fusion Scroll Copeland Scroll UltraTech compressors allow precise temperature control. At any point in the compression process, there are several pockets within the scroll that are compressing gas. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60Hz capacity at AHRI operating conditions of 45°F(7. Product description. (oC)-17. North America. • Allow time for the compressor to cool before servicing. txt) or read book online for free. Copeland Compressor Nomenclature. Also for: Copeland scroll zps67-83kc, Copeland scroll The ZOV*AG compressors with motor code "X" are offered as matched pairs with the EVM/EVH drive, designed in accordance with EN 60335-1. Use a recovery Copeland Scroll Compressors Bom Overview en Gb 4848778 - Free download as PDF File (. The scope of this bulletin will cover the application parameters unique to the ZB*K5E and ZF*K5E refrigeration scrolls with CoreSense™ technology. Compressors with PTCs are indicated by an "S" in the second character of the electrical code, e. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Voltage Tonnage Trane OEM COM # *SF COM # Danfoss COM # Copeland COM #s. 2. 5 5 5. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Copeland ZP Series - Free download as PDF File (. Models Covered In This Guide Are Also Available In Tandem, Trio, Digital, EVI The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. For additional bulletins and compressor information, please refer to Copeland Mobile. Figure 1: Next Generation CoreSense module on Stream compressor 2 Nomenclature • All Copeland Scroll compressors are designed with a discharge check valve that isolates the high pressure discharge gas. 230-3 SF Model Number Nomenclature *SF Compressors available April 2016. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit Copeland Scroll inverter compressor maximizes system efficiency Water chiller (IPLV) Based on ARI roofing machine IEER standard 6 7 Variable speed compressor nomenclature Operating envelope. NOTE: The compressor is only one component which must be combined with many others to build a functional and efficient refrigeration system. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z • All Copeland Scroll compressors are designed with a discharge check valve that isolates the high pressure discharge gas. Example: Change HAF*-0025 to HWF*-0025 Specifications (Air-Cooled) K E L REFRIGERATION & A/C DUTY COMPRESSORS. one module, as well as offering optional protection against high discharge temperature and communication 1. Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PF 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-55 TF 60-3-380 UltraTech™ Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland™ ZPSK5 UltraTech™ Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale The Scroll compressor has been under development at Emerson Climate Technologies since 1979. An example 2 3 Table of Contents Content Page Centers for World-Class Manufacturing Excellence 4 Condensing Unit Overview 6 • ZX Family Condensing Units 10 • KHZ Condensing Units 16 • F-Series Scroll Condensing Unit 20 • Semi-Hermetic Condensing Units 22 •M ulti-Compressor Racks 24 • Water-Cooled Condensing Units 28 Compressor Overview 32 • Scroll Scroll Compressors - Comfort ™• ZR Copeland Scroll Compressor Range for R407C and R134a • ZP Copeland Scroll Compressor Range for R410A • ZP Copeland Scroll Air Conditioning Compressor Range, Optimized for Seasonal Performance • ZPD & ZRD Copeland Scroll Digital™ Compressor Ranges for R410A and R407C Nomenclature 06 Bill of material 06 Operating envelopes 07 • Engineered for optimum performance with today’s chlorine-free refrigerants. 2°C) Copeland R-290 scroll compressor Copeland R-290 fixed speed models are intended for low- to medium-temperature refrigeration applications and are ideally suited for applications such as walk-in and reach- in coolers. Motor Rating Temperature Application H = High M = Medium L = Low A = Optimized for R-134a (COMPACT ONLY) The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. If a compressor’s electrical terminal pin loses its seal, pressurized oil, Copeland Compressor body - Nr of cylinders 2 cylinders 3 cylinders 6 cylinders 8 c linders Compressor technology: D = Discus T = Two-stage Compressor version Stroke / Bore For more detailed information related to voltage ranges for CopelandTM condensing units look on Emerson. 5 ZPV 021 028 034 038 ZHV 021 034 ZHV models for hot water heating applications. Also for: Copeland scroll zp kc series, Copeland scroll zr84kce The Copeland Scroll ™ refrigeration compressor product offering has developed the K5 compressor for the 8 to 15 HP size range. The model number of Emerson Copeland Discus Series Pdf User Manuals. Digit 6, 7, 8 — Capacity. 9. 7. 75 6. Compressor Protection • 2–7. 8 -15 -10 -5 0 5 Compressor Family Series Either a number or a letter established for each product model. It is the most efficient and durable compressor Emerson Climate Technologies The Scroll compressor has been under development at Emerson since 1979. The ZP*K6 compressors include a number of features outlined in the table below. Nomenclature. 8 x 8. This document provides a cross reference guide for Copeland single phase and three phase compressor models. Allow time for the compressor to cool before servicing. 800 = std. 5 to 15 HP). 466. Copeland 2 Ton Scroll Compressor. * Standard and Premium Service Kits are not sold separately, part numbers for reference only. 22 Emerson Compressor & Drive Selection . Copeland Scroll ZPS KC Series air compressor pdf manual download. This should be taken into consideration when implementing a digital control sequence that does not Manuals and User Guides for Emerson Copeland D6D Series Compressor. • All Copeland Scroll compressors are designed with a discharge check valve that isolates the high pressure discharge gas. Old Discus Nomenclature Example: 3DS3A150E-TFD New Discus Nomenclature Example: 3DS3R17ME-TFD 100 = std. is not affiliated with Trane International, Inc. Some usage limitations may apply, but you aren't limited to only compressing PDFs; you can reduce the file size of other document types, like MS Office files, JPG, PNG, GIF, and TIFF without compromising image quality. 5x 10. Copeland Scroll ZP K6 Series air compressor pdf manual download. Copeland Scroll Fusion compressor which combines Emerson’s revolutionary scroll technology and the serviceability of a traditional semi-hermetic compressor. 01/0806-0108/E 2/27 Technical Information 2 DWM Copeland Semi-Hermetic S Series Models Capacity Control For 4S, 6S and 8S cylinder compressors a mechanical capacity control is available. 0 kW) and include common 50 and 60 Hertz, single and three All of the compressors covered in this bulletin are in the high pressures. 5 2 2. Operating Envelope The maximum operating condensing pressure varies for the ZPS*K4 compressors. BRISTOLCOMPRESSORS. Nominal Capacity at Rating Condition Most Common Regions. (Premium Service Kits The compression process of a scroll compressor is described in AE4-1331, Figure 9. Hermetic Compressors – A 2014DS-78 R2 (2/16) 3 Emerson Climate Technologies A F E 10 C 3 E - I A A - 201 Compressor Family Series Either a number or a 100 = std. 5 4. Generation 1 Radial Mechanical Modulation Copeland Scroll UltraTech compressor nomenclature Z P S 30 K 5 E – P F V –130 Z scroll family series AC, R-410A/B UltraTech Nominal Capacity at Rating Condition Capacity Multiplier Copeland Scroll™compressors are manufactured according to the latest U. C6. Note that the same compressor Set your Compressor and Condensing Unit detailed product information result view: Default (All Collapse) Or select from the list of sections below: Default (none) Summary Performance Components Service Parts Features Accessories Electrical Components Drawings Nomenclature Miscellaneous Bill of Materials compressors. Air- or Water The Next Generation CoreSense (or Next Gen CoreSense) is implemented on all Copeland Stream compressors stfrom November 1 , 2019, in replacement of the previous CoreSense Diagnostics. These instructions are general in nature, and have been primarily for fi eld installed and connected sys-tems normally utilizing compressors 2 horsepower in size or larger. 12x 8. rfsx qbhg lrjt gnoxvt tpsmkc cwq cad xyms cjhq gonk